YAOHUA XK3190-D10 WEIGHING INDICATOR
Weighing indicator XK3190-D10 adopts high precision ∑-Δ A/D conversion technology, widely applied in electronic floor scale, electronic truck scale, static railroad truck scale and so on alike static weighing system equipped with 1~8 load cell.
Functional capabilities:
- Accuracy Class III, N=5000
- A/D Conversion Method ∑-Δ
- Input Signal Range -15mV ~ 30mV
- A/D conversion speed 200 times/sec.
- Nonlinearity ≤0.0015%FS
- Load Cell Excitation DC5V; I:120mA
- connection number of load cell 8 at 350 ohm or 16 at 700 ohm
- Load cell connection mode 6 wire, auto compensation for long distance
- Sensitivity 0.5uV/d
- Display 7 bits LED, 7 status indications,3 battery indications
- Clock real clock without effect on power off
- Standard Scoreboard interface (Standard)
- Transmission distance Current loop≤2000 meters
- Serial sending signal by current loop with baud rate 600
- Communication interface (RS232 C standard; RS422 optional)
- Transmission distance RS232C≤30 meters; RS422≤1200 meters
- Parallel sending, able to connect with wide-line printer KX-P1121、KX-P1131、LQ300K;
- Fuse 0.5A
- Print interface (Standard)
- Power supply AC 187~242V,49~51HZ; DC:6V/10Ah
Technical data:
Name | Details |
Model | XK3190-D10 |
Brand | YAOHUA |
Origin | China (Jiangsu) |
Accuracy | Class III,N=5000 |
A/D Conversion Method | ∑-Δ |
Input Signal Range | -15mV ~ 30mV |
A/D conversion speed | 200 times/sec. |
Nonlinearity | ≤0.0015%FS |
Load Cell Excitation | DC5V; I:120mA |
Max. connection number of load cell | 8 at 350 ohm or 16 at 700 ohm |
Load cell connection mode | 6 wire, auto compensation for long distance |
Max. Sensitivity | 0.5uV/d |
Display | 7 bits LED, 7 status indications,3 battery indications |
Clock | real clock without effect on power off |
Standard | Scoreboard interface (Standard) |
Transmission distance | Current loop≤2000 meters |
Serial sending signal by current loop with baud rate | 600 |
Communication interface | ( RS232 C standard; RS422 optional) |
Transmission distance | RS232C≤30 meters; RS422≤1200 meters |
Parallel sending, able to connect with wide-line printer | KX-P1121、KX-P1131、LQ300K; |
Fuse | 0.5A |
Print interface (Standard) | |
Power supply | AC 187~242V,49~51HZ;DC:6V/10Ah |
ZEMIC 1t, 2t, 2t, 5 Ton High Accuracy Digital Load Cell
Description
Single-point load cells are sensors used to measure force or weight in a variety of industrial and commercial applications. Browse our selection of single-point load cells.Specification and Technical Data
Name | Details |
Capacity | Zemic |
Material | B8D |
Ingress Protection | Single Ended Shear Beam |
Application | 2 Ton |
Features | Stainless Steel |
Load Cell Certifications | IP67 |
Output Sensitivity(FS) | Electronics Scale |
Combined Error | Current Calibrated |
Creep Error (30 minutes) | OIML, NTEP, ATEX |
Accuracy Class | 3.0 +/- 0.08 mV/V |
Temperature Effect on Zero | <= +/- 0.023 |
Temperature Effect on Output | <= +/- 0.016 |
Zero balance | OIML R60 C3 |
Maximum Safe Overload | <= +/- 0.015 |
Ultimate Safe Overload | <= +/- 0.011 |
Recommended Excitation Voltage | +/- 1% FS |
Maximum Excitation Voltage | 150% FS |
Input Resistance | 300% FS |
Output Resistance | 5 to 12V DC |
Insulation resistance at 50V DC | 18V DC |
Compensated Temperature Range | 350 +/- 3.5 Ohm |
Operating Temperature Range | 350 +/- 3.5 Ohm |
Load Cell Intervals (nLC)/Divisions | >= 5000 M Ohm |
Cable Length | -10 to +40 Deg C |
Capacity | -35 to +65 Deg C |
Material | 3000 |
Ingress Protection | 6 Meter |
Application | Zemic |
Features | B8D |
Load Cell Certifications | Single Ended Shear Beam |
- Stainless Steel, Welded Seal Construction
- Hostile or Clean Environment
- Food & Beverage Processing
- Chemicals & Plastics Processing
- Tank, Bin & Hopper Weighing
- Batching, Blending & Mixing Systems
ZEMIC 30/40 Ton High Accuracy Digital Load Cell
Specification and Technical Data
Rated capacity: 5ton to 50ton | Operating temperature range: -30 to +70℃ |
Rated output:2.0±0.002mv/v | Maximum safe overload;150% OF R.C |
Combined error: ±0.03% F.S | Ultimate safe overload;200% OF R.C |
Non-repeatability: ±0.02% F.S | Recommended Excitation;10 to 12V DC |
Non-linearity: ±0.02% F.S | Maximum Excitation;15V DC |
Hysteresis error: ±0.02% F.S | Environment protection: IP68 |
Zero balance: ±1% F.S | Input impedance: 750±10Ω |
Creep error(30minutes): ±0.02% F.S | Output impedance: 702±3Ω; 703±5Ω(cable≥15m); |
Temperature effect on zero: ±0.02% F.S | Insulation resistance at 50V DC: ≥5000MΩ |
Temperature effect on output: ±0.02% F.S | Material: nickel-plated alloy steel; |
Compensated temperature range: -10 to +40℃ | Cable length: 5.2meter(5t);8meter(10t); 10meter(15t); 10/12meter(20t);12/16meter(25t~50t),diameter 6mm |